Automotive Components Test Chambers - ACTC

Frankonia’s automotive component testing chamber solution at 1.0m measuring distance.

Can we help you?

We promise to respond within 4 business hours (AEST) or you will receive $100 off your next purchase. Read how it works

  • Radiated emissions (EMI):
    Compliance according to CISPR 25
  • Radiated immunity (EMS):
    Compliance according to DIN/ISO 11452-2
  • Compact chamber design and adapted hybrid absorber lining with Frankosorb®
  • Broad range of accessories
  • Turn-key solution

The ACTC is Frankonia’s solution for compliant radiation tests of automotive components according to DIN/ISO 11452-2 and CISPR 25. The standard version of the ACTC is equipped for measurements from 150 kHz to 18 GHz (40 GHz as option) at 1.0m measuring distance.


A permanent plug-in contact strip is installed between the absorbers to ensure the electrical connection of the test table to the shielding, and includes the test table as required according to CISPR 25. The most important advantage of the ACTC is the compact chamber size and its optimum functionality which fulfils compliance requirements.

Datasheet

View Frankonia Website

ACTC – Automotive Components Testing Chamber

Technical specification

External dimension (L x W x H)

6.380m x 5.480m x 3.750m

Frequency range

150 kHz to 18 GHz (option 40 GHz)

Measuring distance

1.0m

Absorber lining

Walls and ceiling

Optimized lining with ferrite absorbers; partial lining with Frankosorb® hybrid absorbers H450

Floor

Movable absorbers as option; ground plane as option

 

ACTC - Performance

Emission test (EMI)

Full compliance according to CISPR 25 (ALSE requirements)

Immunity test (EMS)

Full compliance according to DIN/ISO 11452-2 (ALSE requirements)


We're here to help

Talk to an expert today.
Our friendly team of highly trained specialists will quickly assist you.

Get a quote technical support 1300 387 326

We promise to respond within 4 business hours (AEST).

Or you will receive $100 off your next purchase. Read how it works.

Largest installation base in Australia

We bring to you the experience of having installed more EMC chambers in Australia than any other company.

Turn-key solution provider

Fuseco can build a complete end-to-end EMC chamber system with all the test equipment fully integrated or alternatively just the chamber or the test equipment.

Customer support

With our experience, brands, pricing levels, expertise and industry leading post-installation customer support, Fuseco have become the industry's most trusted partner for EMC testing.


our brand portfolio

Logo reads "Frankonia" in capital letters and black font with a red design on top of the logo.

Applicable Industries

Top FAQs

VIC - HEAD OFFICE / WAREHOUSE

27 Viking Court

Cheltenham VIC 3192


NSW - SALES OFFICE / WAREHOUSE

29/8-10 Barry Road

Chipping Norton NSW 2170


QLD - SALES OFFICE

1 / 26 Duke Street

Sunshine Beach QLD 4567


WA - SALES OFFICE

67 Howe Street

Osborne Park WA 6017


EMC means "an electronic or electrical product shall work as intended in its environment. The electronic or electrical product shall not generate electromagnetic disturbances (interference), which may influence other products". In other words, EMC deals with problems of noise emission as well as noise immunity of electronic and electrical products and systems. Electromagnetic disturbances occur as conducted interference as well as radiated emissions and immunity problems.

An anechoic chamber is a room designed to completely absorb reflections of electromagnetic waves used for various EMC Testing. They are also insulated from exterior sources of noise. The combination of both aspects means they simulate a quiet open-space of infinite dimension, which is useful when exterior influences would otherwise give false results. The RF anechoic chamber is typically used to house the equipment for performing measurements of antenna radiation patterns, electromagnetic compatibility (EMC) and radar cross section measurements. EMC chambers allow for the performance of fast and efficient EMC radiated tests at a convenient location, without interference from the ambient electromagnetic environment.

The term conducted emissions refers to the mechanism that enables electromagnetic energy to be created in an electronic device and coupled to its AC power cord. Similarly to radiated emissions, the allowable conducted emissions from electronic devices are controlled by regulatory agencies. If a product passes all radiated emissions regulations but fails a conducted emissions test, the product cannot be legally sold.

The term radiated emissions refers to the unintentional release of electromagnetic energy from an electronic device. The electronic device generates the electromagnetic fields that unintentionally propagate away from the device’s structure. In general, radiated emissions are usually associated with non-intentional radiators, but intentional radiators can also have unwanted emissions at frequencies outside their intended transmission frequency band.

Conducted Immunity (also called Susceptibility) is a measure of the ability of electronic products to tolerate the influence of conducted electrical energy from other electronic products and electromagnetic phenomena.

Radiated Immunity (also called Susceptibility) is a measure of the ability of electronic products to tolerate the influence of radiated electrical energy from other electronic products and electromagnetic phenomena.

Simulates disturbances created by radio transmitters operating below 80 MHz (such as AM broadcast transmitters) that would typically be coupled onto a products interface cables.


Test Method

The test signal, amplitude modulated by a 1 kHz sine wave, is injected onto the AC or DC wires via a Coupling, Decoupling Network (CDN) while the frequency is varied. Unshielded cables can be tested using either a CDN, coupling clamp or current injection probe. Shielded cables are tested using direct injection, the signal is coupled through a 100-Ohm resistor onto the shield of the cable under test. The injection level is pre-calibrated using the appropriate calibration jig and is equivalent to the open circuit voltage at the output from the amplifier for an unmodulated signal.


The test level for the residential, commercial and light industrial generic standard is 3 Volts; for heavy industrial equipment the test level is 10 Volts.

Related Resources

Tritium is a global leader in the rapidly expanding industry of EV chargers. Recently they opened a world-class compliance testing facility at the company’s Brisbane headquarters.
It’s time to bring your compliance testing in-house, to save on time and costs – So how do you find the right method to test your products?

We have a Frankonia SAC3Plus EMC chamber that we use for commercial testing. We have some height limitations in our laboratory and its dome shaped design fits very conveniently. We are happy with the performance of the chamber and their absorber design is great. No carbon dust and falling of foam absorbers. Previously we had carbon foam-based absorbers and we literally had to wear a safety hat before entering the chamber.

Terry Stones

LABORATORY MANAGER