Description
The SE-330 is an advanced ground-fault and neutral-groundingresistor monitoring relay that is compliant with Rule10-302 of the 2018 Canadian Electrical Code Part I (CE Code). It measures neutral current, neutral-to-ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact and that it has not been bypassed or shorted. An open NGR renders current sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. A shorted NGR results in higher-than-expected ground-fault current. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum, and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standards, use the SE-330AU.
Resistor Monitoring
The SE-330 combines the measured values of resistance, current, and voltage to continuously determine that an NGR is intact. It is able to detect an open or shorted resistor with or without a ground fault present. Sensing resistors are matched to the system voltage and are used to monitor NGRs on systems up to 72 kV.
Ground-Fault Monitoring
The SE-330 uses an application-appropriate current transformer to reliably detect ground-fault currents as small as 100 mA. DiscreteFourier Transform (DFT) filtering ensures that false trips due to harmonic noise from adjustable-speed drives do not occur. Should the resistor open and a ground fault subsequently occur, the SE-330 will detect the fault through voltage measurement, while other current-only sensing relays would be ineffective.
Pulsing Ground-Fault Location
The SE-330 is capable of controlling a pulsing contactor, which is used to switch the NGR resistance in a pulsing-compatible NGR package. The resulting ground-fault current is distinguishable from charging currents and noise and will only appear upstream of the ground fault, making fault location fast and easy, even without isolating feeders or interrupting loads.
How to monitor NER integrity
Features & Benefits
Continuous NGR monitoring
Detects resistor failure within seconds, reduces transient-overvoltage risk, removes risk of ground-fault-detection failure
Shorted NGR detection
Detects a ground fault on the neutral that could bypass the resistor, ensures fault current is not higher than expected
Ground-fault detection
Main or backup protection to detect a ground fault anywhere on the monitored system
Adjustable pickup (2-100%)
Select greatest sensitivity without false operation, adjustable in 1% increments (MEM setting)
Adjustable time delay (0.1-10 s)
Adjustable trip delay allows quick protection and system coordination
Universal CT compatibility
Allows the use of a CT that gives required ground-fault settings
Programmable output contacts
Two programmable Form C and One programmable Form A (Ground Fault, Resistor Fault, Unit Health)
Selectable contact operating mode
Selectable fail-safe or non-fail-safe operating modes allows connection to shunt or undervoltage breaker coil or alarm circuit (K1, K2, and K3 output contacts)
Analog output (4-20 mA)
Connect an optional PGA-0520 meter or control system
Pulsing output (SE-330 only)
Control the operation of a pulsing ground-fault-location circuit
Trip records
On-board 100-event (with date and time) recorder helps with system diagnostics
Harmonic filtering (DFT)
Eliminate false trips due to harmonic noise from ASDs
Local communications
Mini USB port to view measured values, configure settings, and check event records
Data logging
On-board microSD card (included) can be used for long-term data logging
Network communications
Remotely view measured values and event records, reset trips, and cause a remote trip
Available Protocol Options: IEC 61850 - with dual RJ45, SC Fiber and RJ45, or Dual SC Fiber Interface Modbus TCP and Ethernet/IP - with dual RJ45, SC Fiber and RJ45, or Dual SC Fiber Interface DeviceNet - with CAN interface
Software
PC-interface software (SE-MON330) is available at Littelfuse.com/RelaySoftware
Selectable reset mode
Selectable latching or auto-reset operation
Unit-healthy output
Verifies SE-330 is operating correctly, available as Form A or Form B output contact
Conformal coating
Internal circuits are conformally coated to protect against corrosion and moisture